Christmas fire safety at work comes down to a handful of checks: keep fire exits and escape routes clear of extra stock, store cardboard and waste securely away from the building, keep decorations away from lights and heaters, give every seasonal starter a fire safety induction, and make sure your fire alarm and emergency lighting tests are up to date. None of this is an optional extra. Each check links back to a duty on the responsible person under the Regulatory Reform (Fire Safety) Order 2005.

This guide is for shop owners, office managers and pub or restaurant managers in Colchester and across Essex. It gives you a walk-round checklist to use before the busiest weeks, with the law or official guidance behind each item.

Why fire risk goes up in the run-up to Christmas

Essex County Fire and Rescue Service (ECFRS) set out the problem in a warning to Essex retailers in November 2023. Shops carry extra stock, put up festive decorations and take on seasonal staff who may not know the fire procedures. Fire officers had visited businesses in Tendring and found extra stock and cardboard that was not being stored correctly. As ECFRS business engagement officer Alison Loades put it, "Too many businesses don't recover after the devastation of having a fire."

That warning dates from 2023, but the conditions it describes come round every December. ECFRS's Christmas advice for offices covers trees, decorations near light fittings and keeping exits clear. Blocked escape routes and poorly managed storage are also among the common fire safety failures found during inspections in Essex all year round.

Who is responsible for fire safety at work?

The law places the duty on the "responsible person". GOV.UK explains that this is the employer, owner, landlord, occupier or anyone else with control of the premises, such as a facilities or building manager. Where more than one person is responsible, for example a tenant business and its landlord, you must work together.

Since 1 October 2023, the responsible person must record the fire risk assessment in full, including all the findings, along with the fire safety arrangements for the premises. The old threshold, which only required a written record from businesses with five or more employees, has gone (GOV.UK guidance on section 156 of the Building Safety Act 2022). GOV.UK is clear that you could be fined or go to prison if you do not follow fire safety regulations.

The pre-Christmas fire safety walk-round checklist

Walk the premises with this list before your Christmas stock arrives, then again once the decorations are up. Print it, tick it off, and keep the completed copy with your fire safety records.

Check

What good looks like

Why (law or official guidance)

1. Fire exits and escape routes

Every exit opens easily. Nothing sits in corridors, on stairs or in front of final exit doors, even "just for today".

Article 14 of the Fire Safety Order: routes to emergency exits and the exits themselves must be "kept clear at all times". The Home Office guide for offices and shops advises checking escape routes daily.

2. Extra stock

Overflow stock is kept in storerooms the public cannot enter. It is not piled against electrical equipment or heaters, and not pushed into roof voids.

Home Office guide, offices and shops, Part 2 section 1.2.

3. Cardboard and waste

Packaging is cleared often and stored securely outside, away from the building and out of reach of arsonists. Wheelie bins are secured so they cannot be moved against the wall. Skips are normally at least 6 metres from any part of the premises.

ECFRS retailer warning (2023). Home Office guide, Part 2 section 1.1.

4. Decorations and displays

Nothing hung near or over light fittings, lamps or heaters. Displays kept out of corridors and foyers. Fire-resistant display materials used where possible.

ECFRS office advice (2023). Home Office guide, Part 2 sections 1.2 and 1.11.

5. Christmas trees

Real trees watered daily, kept away from candles, naked flames and electrical items, and not blocking any exit, corridor or doorway.

ECFRS office advice (2023).

6. Festive lights

Bought from a reputable retailer, checked for damaged wires or plugs before use, outdoor-rated if used outside and connected through a 30mA RCD-protected socket. No overloaded sockets. Switched off when the building closes.

Electrical Safety First. ECFRS office advice (2023).

7. Fire doors

Not wedged open for parties or deliveries. Each door closes fully onto its frame.

Home Office guide, Part 1 steps 3.2 and 3.4.3. Monthly fire door checks are listed at step 3.4.6.

8. Fire alarm

Tested weekly and the result logged. Control panel checked daily for faults.

Home Office guide, Part 2 section 2.5: systems "should be tested once a week" and control equipment checked "at least every 24 hours". Article 17 requires fire safety equipment to be properly maintained.

9. Emergency lighting

Monthly function test done and logged. Annual full discharge test in date. Failed fittings reported and repaired.

Home Office guide, Part 2 section 5. Article 14(2)(h) requires emergency lighting on routes and exits that need it.

10. Seasonal and agency staff

Every new starter has had a fire safety induction on their first day.

Article 21 of the Fire Safety Order. Home Office guide, Part 1 step 4.3 and Part 2 section 7.4.

11. Candles and naked flames

Use restricted and controlled. No candles near trees, decorations or furnishings.

Home Office guide, small and medium places of assembly, step 3.3. ECFRS office advice (2023).

12. Fire risk assessment

Reviewed and updated if the Christmas layout, stock levels or use of the building has changed significantly.

Article 9(3) of the Fire Safety Order.

If your emergency lighting tests have slipped, our emergency lighting installation and testing service can bring the system and the logbook back up to date.

Seasonal staff: what a first-day fire induction should cover

Article 21 requires the responsible person to give employees adequate fire safety training when they are first employed, and again when they are exposed to new or increased risks. The Home Office guide for offices and shops says all staff should receive basic fire safety induction training, and its checklist asks specifically whether temporary or agency staff have been told about the fire safety arrangements.

A short induction on the first shift should cover:

  • how to raise the alarm, including where the nearest call point is;

  • every escape route from where they will be working, including back and side exits;

  • where to go once outside;

  • who calls 999. ECFRS states that it will not provide an emergency response to calls generated by automatic fire alarm systems unless a 999 call confirms a fire or physical signs of fire, or the building has been granted an exemption. Our guide on why Essex Fire may not attend your automatic fire alarm explains what that means for your emergency plan;

  • your Christmas house rules: no stock in escape routes, no wedging fire doors, and decorations only where agreed.

The same guide says fire drills should take place at least once a year, or as determined by your fire risk assessment, and that high staff turnover may mean drills are needed more often. If you take on a large seasonal team, factor that in.

When does a Christmas layout change mean reviewing your fire risk assessment?

Article 9(3) says the assessment must be reviewed regularly to keep it up to date, and particularly if there is reason to suspect it is no longer valid or there has been a significant change in the matters it relates to. Where the review shows changes are needed, you must make them.

A few strings of lights in an office will not normally change your assessment. A review is sensible if, for example:

  • display stands or extra shelving narrow the aisles or the routes to exits;

  • overflow stock takes over a room or area that was not previously used for storage;

  • a pub or restaurant expects much larger numbers than usual, or hires out a room for private functions;

  • portable heaters, extra lighting or extra cooking equipment are brought in.

Record whatever you change. If you are not sure whether a change counts as significant, ask a competent fire risk assessor or contact your local ECFRS fire safety officer through the ECFRS business fire safety pages.

Extra points for pubs, restaurants and hospitality venues

The Home Office guide for small and medium places of assembly adds points that matter for busy venues in December:

  • restrict and control the use of naked flames such as candles;

  • make sure display materials, including artificial and dried foliage, are fire-retardant or treated with a fire-retardant product;

  • keep cooking and catering equipment properly installed, used and maintained;

  • at times of high usage, check your escape routes can cope, and restrict the number of people in the premises if necessary;

  • for private hire and one-off functions, make sure it is clear who the responsible person is for each event.

Christmas fire safety at work: frequently asked questions

Are Christmas decorations allowed at work?

Yes. Home Office guidance treats Christmas decorations as an extra risk to consider in your fire risk assessment, not something you must ban. ECFRS advises offices to keep decorations away from overhead lights and lamps, because they are usually very flammable, and to make sure trees and decorations do not block corridors, fire exits or doorways.

Can I keep extra stock by a fire exit for a few days?

No. Article 14 requires routes to emergency exits, and the exits themselves, to be kept clear at all times. There is no exception for busy periods. If you are running out of space, ECFRS's advice is to manage stock carefully and avoid over-ordering.

What happens if a fire safety officer finds problems?

ECFRS carries out fire safety audits and inspections, and fire and rescue authorities can issue fire safety notices requiring you to make changes. ECFRS publishes a register of notices issued under the Fire Safety Order. GOV.UK warns that you could be fined or go to prison if you do not follow fire safety regulations.

Book a pre-Christmas fire safety review

If your walk-round turns up problems, or you have not reviewed your fire risk assessment since the layout last changed, it is worth getting it checked before the rush. Advanced Protection carries out fire risk assessments and installs fire alarms and emergency lighting for businesses, landlords and estate agents across Colchester and Essex. We start with a consultation, then give you a written quote. Call 01255 860018 or contact us online.